In a potentiometer circuit cell of emf 1.5

WebIn a potentiometer circuit a cell of EMF 1.5 V gives balance point at 36 cm length of wire. If another cell of EMF 2.5 V replaces the first cell, then at what length of the wire, the balance point occurs ? Q5. Potentiometer measures the potential difference more accurately than a voltmeter, because : Q6. WebIn a potentiometer circuit a cell of EMF 1.5 V gives balance point at 36 cm length of wire. If another cell of EMF 2.5 V replaces the first cell, then at what length of the wire, the balance point occurs ?

260 11-1 EXPERIMENT 11 THE POTENTIOMETER I. THEORY

WebIn a potentiometer arrangement, a cell of emf 1.25 V gives a balance point at 35.0 cm length of the wire. If cell is replaced by another cell and the balance point shifts to 63.0 cm, what is the emf of the second cell? Solution: The potential gradient remains the same, as there is no change in the setting of standard circuit. Question 13. WebSep 15, 2024 · In a potentiometer circuit a cell of EMF 1.5 V gives balance point at 36 cm length of wire. If another cell of EMF 2.5 V replaces the first cell, then at wha...... in an alluring charming way https://triple-s-locks.com

A cell of internal resistance 1.5 ohm and of e.m.f. 1.5 V ... - Toppr

WebMay 12, 2024 · In a potentiometer circuit a cell of EMF 1.5\, V 1.5V gives balance point at 36\, cm 36cm length of wire. If another cell of EMF 2.5\, V 2.5V replaces the first cell, then at what length of the wire, the balance point occurs ? NEET - 2024 Updated On: May 12, 2024 60 cm 21.6 cm 64 cm 62 cm Correct Answer: A Suggest Corrections Detailed Solution WebAnother possible way is to increase the potential droop across the potentiometer wire by increasing the voltage of driver cell. Example: The Fig. shows a 2.0 V potentiometer used for the determination of internal resistance of a 1.5 V cell. The balance point of the cell in open circuit is 76.3 cm. WebQ 28. In a potentiometer circuit a cell of EMF 1.5 V gives balance point at 36 cm length of wire. If another cell of EMF 2.5 V replaces the first cell, then... duty of care in child care legislation

In a meter bridge, the balance point is found at a distance l1 with ...

Category:In a potentiometer circuit a cell of EMF 1.5V gives balance point at ...

Tags:In a potentiometer circuit cell of emf 1.5

In a potentiometer circuit cell of emf 1.5

NCERT Solutions for Class 12 Physics Chapter 3 Current Electricity

WebIn a potentiometer circuit a cell of EMF 1.5 V gives balance point at 36 cm length of wire. If another cell of EMF 2.5 V replaces the first cell, then at what length of the wire, the … WebAug 7, 2024 · In potentiometer experiment a cell of emf. 1.5V connected in the secondary circuit gives a balancing length of 165cm of the wire. If a resistance of 5 is connected …

In a potentiometer circuit cell of emf 1.5

Did you know?

WebA potentiometer wire of length 1 m is connected to a driver cell of emf 3 V as shown in the figure. When a cell of 1×5 V emf is used in the secondary circuit, the balance point is … WebIf not, how will you modify the circuit? 3.23 Figure 3.34 shows a 2.0 V potentiometer used for the determination of internal resistance of a 1.5 V cell. The balance point of the cell in open circuit is 76.3 cm. When a resistor of 9.5 Ω is used in the external circuit of the cell, the balance point shifts to 64.8 cm length of the potentiometer ...

Web8 rows · Jul 8, 2024 · A potentiometer circuit has been set up for finding the internal resistance of a given cell. ... WebA potentiometer wire of length 1 m is connected to a driver cell of emf 3 V as shown in the figure. When a cell of 1.5 V emf is used in the secondary circuit, the balance point is found to be 60 cm. On replacing this cell and using a cell of unknown emf, the balance point shifts to 80 cm.Calculate unknown emf of the cell.

WebFigure shows a potentiometer circuit for comparison of two resistances. The balance point with a standard resistor R = 1 0. 0 Ω is found to be 58.3 cm, while that with the unknown resistance X is 68.5 cm. Determine the value of X. What might you do if you failed to find a balance point with the given cell of emf ϵ? WebMar 8, 2024 · A potentiometer is an accurate device to make electrical measurements of emf because the method involves a condition of no current flow through the …

WebIn a potentiometer circuit, a cell of emf 1.5 V gives a balance point at 36 cm length of wire. If another cell of emf 2.5 V replaces the first cell, then at what length of the wire, the balance point occurs? 1. 64 cm 2. 62 cm 3. 60 cm 4. 21.6 cm Q 473: 74 % From NCERT NEET - 2024 (1) (2) (3) (4) Subtopic: Meter Bridge & Potentiometer

WebThe Potential difference across a resistance in the circuit is balanced at 1.25 m . If a voltmeter is connected across the same resistance, it reads 0.65 V. ... a standard cell of emf 1.5V is balanced at 375cm length of potentiometer wire. ... A voltmeter reading upto 100 mV is calibrated by a potentiometer. An emf of 1.08 V is balanced across ... duty of care in child care examplesWebQ.11 In a potentiometer arrangement. E1 is the cell establishing current in primary circuit. E2 is the cell to be measured. AB is the potentiometer wire and G is a galvanometer. Which of the following are the essential condition for balance to be obtained. (A) The emf of E1 must be greater than the emf of E2. in an allusion the importanceWebIn a potentiometer circuit a cell of EMF 1.5 V gives balance point at 36 cm length of wire. If another cell of EMF 2.5 V replaces the first cell, then at what length of the wire, the … in an allusion the importance in what a wordWebIn a potentiometer a cell of emf 1.5 V gives a balanced point at 32 cm length of the wire. If the cell is replaced by another cell then the balance point shifts to 65.0 cm then the emf … in an alternate mannerWebIn a potentiometer circuit, a cell of emf 1.5 V gives a balance point at 36 cm length of wire. If another cell of emf 2.5 V replaces the first cell, then at what length of the wire, the … in an aloof manner crosswordWebApr 3, 2024 · (i) same polarity, (ii) opposite polarity. The configuration is connected to a galvanometer and a jockey to the potentiometer. The balancing lengths in the two cases … in an aloof manner crossword cluehttp://classes.oc.edu/PhysicsLab/POTENTIO.htm in an alphabetic file which is filed first